12V 150AH EPS Battery Emergency Power Battery With Flame Retardant ABS Case
Place of Origin:China/Malaysia
Brand Name:JYC
Certification:UL CE IEC Rohs
Model Number:GP150-12
Packaging Details:Carton+Pallet
Delivery Time:30 work days
Payment Terms:T/T,L/C
Supply Ability:23 million pcs/Year
Inquiry Now
Get A Quote
Specifications
Highlight Features
150AH EPS Battery
,
12V EPS Battery
,
EPS Emergency Power Battery
Type:
GPbattery
Color:
Grey / Black / Customizable
Voltage:
12V
Capacity:
150AH
Dimension:
481*170*242*245
Product Description
Introduction to 12V150AH EPS Emergency Power Battery
Power your peace of mind with the 12V 150Ah dedicated battery for EPS emergency power systems. Engineered to meet stringent safety standards, this high-performance backup power source delivers rock-solid reliability and stable output exactly when it's needed most. Whether it's a sudden grid outage or an unexpected power fluctuation, our battery keeps your fire alarm systems, emergency lighting, and critical safety equipment running without interruption. With exceptional wide-temperature adaptability, an extended float service life, and zero-maintenance operation, you get maximum protection with minimal effort. Choose confidence. Choose safety. Choose the battery that never sleeps when you need it most.
I. Core Product Parameters
Nominal Voltage & Capacity: 12V / 150Ah (10HR rate), perfectly matched with EPS systems, fire alarm control panels, NAC extenders, and auxiliary power modules.
Discharge Characteristics: 10-hour rate ≥150Ah; 1-hour rate ≥100.5Ah; provides reliable backup for extended duration under typical EPS and fire alarm load conditions.
Internal Resistance: Internal resistance ≤5mΩ when fully charged; self-discharge rate ≤2% per month at 25°C, suitable for low-maintenance residential and commercial installations.
Charge Parameters: Recommended float voltage: 13.62–13.80V; equalization voltage: 14.1–14.4V; built-in overcharge tolerance ensures safe operation with standard EPS and fire alarm power supplies.
II. Core Technical Advantages
(1) High Reliability for Fire Safety
Adopts valve-regulated sealed lead-acid technology with flame-retardant ABS case (UL94 V-0) and double leak-proof seals, meeting fire safety equipment enclosure requirements.
(2) Wide Temperature Adaptability, Coping with Complex Working Conditions
Operating temperature range: -20°C to +50°C (capacity output ≥90%), with vibration/shock resistance, eliminating the need for additional temperature control in most fire alarm environments.
(3) Long Life & Maintenance-Free
Optimized grid alloy and paste formula provides float life up to 6–8 years (standby use) and cycle life ≥300 cycles. AGM separator ensures zero maintenance—no water or acid refill needed.
(4) Smart Compatibility
Easily integrates with most EPS systems, fire alarm panels, addressable systems, and conventional control panels. Standard terminal types and compact dimensions allow direct drop-in replacement for GP150-12 and equivalent models.
III. Application Scenarios
EPS (Emergency Power Supply) Systems: Primary backup power for emergency lighting, fire pumps, smoke exhaust fans, and other critical fire safety loads.
Fire Alarm Control Panels (FACP): Backup power for conventional & addressable alarm systems.
Emergency Lighting & Voice Evacuation Systems: Ensures illumination and voice guidance during fire.
Fire Suppression Control Systems: Supports gas or water suppression controls in server rooms and industrial plants.
Unattended Substations & Pump Rooms: Long-term maintenance-free operation with automatic backup upon mains failure.
IV. Quality Assurance and Compliance
Compliance Standards: Strictly conforms to IEC 60896-21/22, GB/T 19638, and UL 1989 (fire alarm system battery standard), fully meeting fire regulatory requirements.
Quality Inspection: Full production process follows ISO 9001 and ISO 14001 standards, with 100% final voltage, capacity, and leak testing to ensure consistent performance.
After-sales Support: Comprehensive warranty (typically 12 months) with technical support, failure analysis, and replacement service to ensure long-term system readiness.
Introduction to Centralized Emergency Lighting Battery Purpose-built for modern building safety infrastructure, the 12V17AH Centralized Emergency Lighting Battery utilizes valve-regulated, sealed lead-acid (VRLA) technology, making it an ideal choice for centralized emergency lighting systems. When ...
Introduction to Centralized Emergency Lighting Battery Purpose-built for modern building safety infrastructure, the 12V24AH Centralized Emergency Lighting Battery utilizes valve-regulated, sealed lead-acid (VRLA) technology, making it an ideal choice for centralized emergency lighting systems. When ...
Introduction to 12V 38AH EPS (Emergency Power Supply) Battery The 12V 38AH dedicated battery for EPS (Emergency Power Supply) systems is a standard-compliant backup power source, engineered for high reliability and stable output during emergencies. Core advantages include wide temperature adaptabili...
Introduction to Centralized Emergency Lighting Battery Designed for modern building safety systems, the 12V 38AH Centralized Emergency Lighting Battery is a valve-regulated, sealed lead-acid (VRLA) power source developed specifically for centralized emergency lighting systems. It delivers stable, ...
Leave a Message
We will call you back soon!
Your message must be between 20-3,000 characters!
Please check your E-mail!
SUBMIT
More information facilitates better communication.
Mr
Mr
Mrs
OK
Submitted successfully!
We will call you back soon!
OK
Leave a Message
We will call you back soon!
Your message must be between 20-3,000 characters!
Please check your E-mail!
SUBMIT
Please leave your correct email and detailed requirements (20-3,000 characters).