Specifically engineered for server room environments, the 12V65AH Server Room UPS Battery is a valve-regulated, sealed lead-acid (VRLA) power source designed to provide reliable backup for rack-mounted and standalone UPS systems. It ensures continuous power delivery to servers, network switches, storage arrays, and other critical IT equipment during mains interruptions.
I. Core Product Parameters
Nominal Voltage & Capacity: 12V / 65Ah(10HR rate), offering broad compatibility with industrial backup systems, power distribution units, and auxiliary modules.
Discharge Characteristics: 10-hour rate ≥65Ah; 1-hour rate ≥43.6Ah;providing dependable extended-duration backup under typical server rack load conditions.
Internal Resistance: Internal resistance ≤12mΩ when fully charged; self-discharge rate ≤2.5% per month at 20°C, this battery is ideally suited for low-maintenance server room deployments.
Charge Parameters: Recommended float voltage: 13.62–13.80V; equalization voltage: 14.1–14.4V; Built-in overcharge tolerance guarantees safe, reliable operation with standard server room UPS charging systems.
II. Core Technical Advantages
High Reliability for Mission-Critical IT Infrastructure Built around valve-regulated, sealed lead-acid technology, the battery features a flame-retardant ABS casing (UL94 V-0 rated) and double-layer leak-proof seals. This robust construction meets the stringent safety requirements of modern server rooms and data centers.
High Reliability for Industrial Safety Built around valve-regulated, sealed lead-acid technology, the battery features a flame-retardant ABS casing (UL94 V-0 rated) and double-layer leak-proof seals. This construction meets the most stringent industrial safety requirements, including those for fire-sensitive environments
Wide Temperature Tolerance for Demanding Conditions Operational across a broad temperature spectrum from -20°C to +50°C, the battery retains ≥90% of its rated capacity even under thermal stress. Its excellent vibration and shock resistance removes the need for additional climate control in most industrial settings — from hot factory floors to cold storage warehouses.
Long Life and Zero Maintenance
Thanks to an optimized grid alloy and advanced paste formula, the battery delivers a float service life of 6–8 years in standby applications and supports ≥300 charge-discharge cycles. The AGM separator technology eliminates any requirement for water or acid refills, drastically cutting operational overhead for plant engineers.
III. Application Scenarios
Server Room UPS Systems: Serves as the primary backup energy source for UPS units protecting physical servers, virtual hosts, and storage area networks (SANs).
Fire Alarm Control Panels (FACP): Provides backup power for conventional and addressable alarm systems within industrial facilities.
Emergency Lighting & Voice Evacuation Systems: Ensures illumination and voice guidance remain operational during plant emergencies or power failures.
IT Equipment Closets & Edge Data Centers: Supports small-to-medium server rooms, branch office IT closets, and edge computing nodes where space is limited but uptime is critical.
IV. Quality Assurance and Compliance
Compliance Standards: Strictly conforms to IEC 60896-21/22, GB/T 19638, and UL 1989 (fire alarm system battery standard), fully meeting fire regulatory requirements.
Quality Inspection: Full production process follows ISO 9001 and ISO 14001 standards, with 100% final voltage, capacity, and leak testing to ensure consistent performance.
After-sales Support: Comprehensive warranty (typically 12 months) with technical support, failure analysis, and replacement service to ensure long-term system readiness.
Introduction to HR12112W High-Rate Discharge AGM Battery Specifically engineered for server room environments, the HR12112W is a valve-regulated, sealed lead-acid (VRLA) high-rate discharge battery designed to provide reliable backup for rack-mounted and standalone UPS systems. It ensures continuous ...
Introduction to IT Cabinet Backup Battery Designed specifically for modern data center environments, the 12V55AH IT Cabinet Backup Battery is a valve-regulated, sealed lead-acid (VRLA) power solution tailored for rack-level backup applications. Whether deployed inside standard 19-inch IT cabinets, ...
Introduction to 2V300AH Lead-Acid Battery for Data Centers The 2V300AH valve-regulated sealed lead-acid battery is an industrial-grade energy storage product tailored for data centers’ UPS backup power systems. Adopting VRLA technology, it can be connected in series to fit various backup power ...
Introduction to Modular UPS System Battery12V100AH The FT100-12 12V 100AH is a high-performance, valve-regulated sealed lead-acid (VRLA) battery, engineered specifically for modular UPS (Uninterruptible Power Supply) systems. Designed to meet the dynamic power demands of modern modular UPS ...
Leave a Message
We will call you back soon!
Your message must be between 20-3,000 characters!
Please check your E-mail!
SUBMIT
More information facilitates better communication.
Mr
Mr
Mrs
OK
Submitted successfully!
We will call you back soon!
OK
Leave a Message
We will call you back soon!
Your message must be between 20-3,000 characters!
Please check your E-mail!
SUBMIT
Please leave your correct email and detailed requirements (20-3,000 characters).